missing and, if applicable, out-of-date carts.
4. Enhancement. A new Relay Queue Maintenance dialog has been added. The dialog displays all
active Start Play tasks that use a Cart Rotation List. Cart rotations can be modified by adding,
editing and deleting cart numbers in the rotation. The Next-to-Play property can also be modified.
Changes made are active until XStudio is restarted. Users can also change the Current Voice
setting manually in this dialog. See the topic on Using the XStudio Relay Queue Maintenance
Dialog for more information.
5. Enhancement. Time-Approximate Directive handling in Satellite Mode has been implemented to
support automated sports broadcasts and similar events where breaks are sequence-sensitive
rather than time sensitive. The log now distinguishes between and displays the next fixed time
directive (NxtU =>) and time-approximate directive (NxtA =>). Users can manually mark the next
time-approximate directive to be used to handle situations where XStudio needs to be
synchronized with the next network break event. An example of how to use this functionality is
discussed in the Satellite Programming - Special Events topic.
6. Enhancement. Functionality to execute an Action at the start of playback for a specific cart has
been implemented. This feature can be enabled or disabled in Preferences and is disabled as a
default. For additional information, review the Embed an Action in a Cart topic.
7. Enhancement. At start-up, XStudio now scans the log from midnight to current time and will
update the Current Voice property if any Set Voice directives are found.
8. Enhancement. A menu item has been added to optionally display the inventory AuxMark length in
the log Length field (View | Log Display | Use Inventory Length on Logs). When enabled,
displayed log items will have the matching cart's inventory AuxMark length value instead of the
original log length value. Note this feature is display-only, the underlying log is not changed.
9. Enhancement. An cart's (audio item's) Agency field information is now passed to the audit data
file for reporting purposes.
10. Enhancement. You can now clear an entire page of hot buttons in the Cart Wall dialog. A toolbar
button or pop-up menu item can be used to reset all hot buttons on a selected page to an
unassigned state.
11. Enhancement. XStudio now detects Windows 8 and Windows Server 2012 operating systems
and adjusts its display accordingly.
12. Enhancement. When an updated log is detected and is being merged (spliced) with the active log,
if no matching directives are found on the active log and the new log has content at times beyond
the active log's last log record, XStudio will scan the later times on the updated log and merge
(splice) the new content if there is a valid directive at a later time on the updated log.
13. Enhancement. Documentation has been updated to include additional information about the
XStudio audit data file structure. See the topic Audit File Specification for additional information.
14. Change. When monitoring for files that might have changed, XStudio now tracks changes based
on UTC time. This approach reduces the possibility of a change incorrectly being detected in
circumstances where XStudio is operating in a time zone that uses DST.
15. Fix. When a user attempted to register XStudio by copying and pasting the registration key into the
registration dialog, the registration key would be invalid because the user inadvertently copied
leading spaces instead of just the registration key text. Now, any extraneous spaces are removed
when the user pastes the registration key into the dialog. Additional feedback is provided when
manually entering a registration key that is not the correct length, which can occur if a character is
missed in typing or if copying only a portion of the registration key and pasting it.
16. Fix. Saving an edited Action in the Automation Setup dialog would occasionally be done
incorrectly, resulting in the wrong Action being updated. The problem could occur if the user began
editing an Action and while editing, another Action was executed by XStudio. XStudio now double-